Class III Biological Safety Cabinet

Short Description:

Class III Biosafety Cabinet is totally enclosed and gas-tight, it also can meet the requirement of operating Class I, II, III, IV pathogenic factor. It can be used in P3,P4 laboratory.


Product Detail

Brochures

Product Tags

Parameter

Model BSC-1100IIIX BSC-1500IIIX
External Size(W*D*H) 1540*880*2000 mm 1790*880*2080 mm
Internal Size(W*D*H) 910*650*660 mm 1165*650*660 mm
Pass Box Size(W*D*H) Internal Size:430*330*355mm
External Size:575*425*495mm
Gloves One pair of 800mm butyl rubber gloves
Front Window 8 mm toughened glass, anti-ultraviolet radiation
Display LCD display
Pre-filter Polyester fiber, washable
Pressure ≥ negative120 Pa
ULPA Filter Air supply filter: Efficiency 99.9995% at 0.12μm
First exhaust filter: Efficiency 99.9995% at 0.12μm
Second exhaust filter: Efficiency 99.9995% at 0.12μm
Noise NSF 49 ≤61dB/EN 12469≤48dB
Alarm Audio and visual alarm, abnormal pressure; filter replacement
Work Zone Material 304 stainless steel
Illumination ≥ 1000 lux
Consumption 1200W 1300W
LED Lamp 12W*2 16W*2
UV Lamp 18W*2 ,8W*1 30W*2, 8W*1
Emission of 253.7 nanometers for most efficient decontamination
Power Supply AC220V±10%, 50/60 Hz;110V±10%,60Hz
Gross Weight 350kg 450kg
Package Size(W*D*H) 1635*1062*2160mm 1890*1065*2240mm
Standard Accessories Gloves, fluorescent lamp, UV lamp*4, remote control, pressure meter, drain valve

Class III Biosafety Cabinet is totally enclosed and gas-tight with ULPA filtered supply and exhaust air. Work is performed with long-sleeved gloves. The cabinet is kept under negative pressure of at least 120Pa, and airflow is maintained by a dedicated exterior exhaust system. It can protect the operator, product and environment.

Pass Box Pressure Meter
Double doors with interlock function and UV lamp. Display the pressure of work zone.
UV Lamp LCD Display
Emission of 253.7 nanometers for most parameters efficient decontamination. Large diaplay is easy to monitor the pressure for work zone and three filters.

Advantage

- With memory function in case of power-failure.

- UV lamp ensures work area sterilization effectively.

- An angled cabinet front ensure an ergonomic working posture.

- Exhaust air is double-filtered through high-quality ULPA filters with typical efficiency of 99.9995% for 0.12μmparticles.