Mini PCR Work Station

Short Description:

The Mini PCR Work Station is a device that provides safe and environmental protection for the rapid nucleic acid detection process in fever clinic and emergency clinic of hospitals. The equipment is divided into three areas, namely reagent preparation area, specimen preparation area and amplification analysis area.


  • :
  • Product Detail

    Brochure

    Product Tags

    Advantage

    1.The multi-function console is divided into three areas, and the areas do not interfere with each other; at the same time, the three areas are closely designed to reduce the sample transfer time between areas and improve the efficiency of rapid nucleic acid detection.
    2.The reagent preparation area is a positive pressure environment, which can protect the reagent preparation from external pollution and protect the reagent.
    3.The specimen preparation area is a negative pressure environment, which can not only protect personnel from harmful aerosol infection, but also protect samples from external pollution, and also protect the external environment from pollution.
    4.The amplification analysis area is a negative pressure environment, which can not only protect personnel from harmful aerosol infection, but also protect the external environment from pollution

    PCR laboratory

    1.Clean bench; 2. Medicine refrigerator; 3. UV Disinfection  trolley; 4. Low temperature refrigerator; 5. Metal  bath; 6. Centrifuge; 7. Water bath; 8. Nucleic extractor; 9. Pipette; 10. biosafety cabinet; 11. PCR machine; 12. autoclave; 13.Vortex mixer

    area product function quantity brand Model
    Reagent preparation area Clean bench Configure reagents 1 OLABO BBS-SDC
    Centrifuge Centrifuge samples 1 OLABO Mini-12
    Vortex mixer Mix the sample 1 OLABO 88882010
    Metal bath Reagent dissolving and heating 1 OLABO 88870005
    Pipette Pipetting 4 OLABO 0.5-10µl
    10-100μl
    20-200μl
    100-1000μl
    Pipette holder Place the pipette 1 OLABO Linear
    Low temperature refrigerator Store reagents 1 OLABO BDF-25V270
    Medicine refrigerator Store reagents 1 OLABO BYC-310
    UV disinfection Trolley Space disinfection 1 OLABO MF-Ⅱ-ZW30S19W
    Biosafety transport box Sample transportation 1 OLABO QBLL0812
    Specimen preparation area Biological safety cabinet Sample processing 1 OLABO BSC-1500IIB2-X
    Water bath Sample inactivation 1 OLABO HH-W600
    Vortex mixer Mix the sample 1 OLABO 88882010
    Centrifuge Sample centrifugation 1 OLABO TG-16W
    TGL-16M
    OLABO Mini-12
    Pipette Pipetting 4 OLABO 0.5-10µl
    10-100μl
    20-200μl
    100-1000μl
    Pipette holder Place the pipette 1 OLABO Linear
    Nucleic Acid Extractor Extract nucleic acid 1 OLABO BNP96
    Low temperature refrigerator Sample storage 1 OLABO BDF-86V348
    Medicine refrigerator Reagent storage 1 OLABO BYC-310
    UV disinfection Trolley Space disinfection 1 OLABO MF-Ⅱ-ZW30S19W
    amplification analysis area PCR machine Sample amplification test 1 OLABO MA-6000
    Low temperature refrigerator Store samples 1 OLABO BDF-25V270
    UV disinfection Trolley Space sterilization 1 OLABO MF-Ⅱ-ZW30S19W
    Disinfection area Autoclave Disinfection of surgical instruments 1 OLABO BKQ-B75II
    Experimental consumables Tip Use with pipette According to actual needs OLABO TF-100-R-S
    TF-1000-R-S
    TF-300-R-S
    TF-200-R-S
    PCR tube Use with a fluorescent quantitative PCR instrument According to actual needs OLABO PCR-0208-C
    PCR-2CP-RT-C
    Centrifuge tube Store reagent samples or use with centrifuge According to actual needs OLABO MCT-150-C
    Sampling tube Collect samples 1 OLABO
    Nucleic Acid Extraction Kit Use with nucleic acid extractor According to actual needs OLABO
    Protective consumables Medical masks Protective Equipment According to actual needs OLABO
    protective suit Protective Equipment According to actual needs OLABO 
    Disposable isolation gown Protective Equipment According to actual needs OLABO
    Gloves Protective Equipment According to actual needs OLABO
    Alcohol Disinfection supplies According to actual needs OLABO 500ml
    Hand sanitizer Disinfection supplies According to actual needs OLABO 500ml

    PCR laboratory

    1. P2 sterile room (excluding buffer room) is equipped with a set of clean air-conditioning system.

    2. The storage room for one-time change of shoes and rain gear, the secondary dressing room, the washing room and the buffer room are each equipped with a split purification air-conditioning system and exhaust fan.

    3. The outdoor fresh air enters the computer room through the primary filter, and then is sent to the high efficiency filter (supply vent) on the top of the clean room through the air conditioner, medium-efficiency filter, and pressurized fan. Each vent is equipped with air volume adjustment. Valve for air volume distribution and pressure difference adjustment.

    4. The air outlet at the end of the air exhaust system is 0.3 meters above the ground, and there is an air volume regulating valve for air volume adjustment. The exhaust main pipe must be installed with a non-return room to prevent the exhaust air from flowing backward.
    5. The temperature probe is set in the main return air duct.


  • Previous:
  • Next:

  • Download:Mini PCR Work Station

    Mini PCR Work Station

  • Related Products