Top Quality China Hospital Movable Types Baby Medical Phototherapy Unit Neonatal Infant Radiant Warmer Price Infant Incubator CE Approved
Being supported by an advanced and specialist IT team, we could give technical support on pre-sales & after-sales services for Top Quality China Hospital Movable Types Baby Medical Phototherapy Unit Neonatal Infant Radiant Warmer Price Infant Incubator CE Approved, For anyone who is fascinated in any items, be sure to truly feel totally free to speak to us for further more details or be sure to deliver us email immediately, we will reply you in 24 hrs as well as the most effective quotation will probably be provided.
Being supported by an advanced and specialist IT team, we could give technical support on pre-sales & after-sales services for Baby Incubator, China Infant Incubator, Now, with the development of internet, and the trend of internationalization, we have decided to extend business to overseas market. With the propose of bringing more profits to oversea customers by providing directly abroad. So we have changed our mind, from home to abroad, hope to give our customers more profit, and looking forward to more chance to make business.
Parameter
neral parameters | Item | Specifications |
Power supply | AC220V,50/60Hz(Standard) 1320VA; 110V 60Hz(Optional) | |
Size(L*W*H) | 950*645*(1250-11450) mm | |
Maximum heater output power(220VAC) | Air chamber heater:330W; Water tank heater:155W | |
Auxiliary network power output | AC220V/50Hz, both maximum permissible currents are 220V 1.5A | |
Heater indication | 0~100%, 10% increasing amount | |
Temperature control mode | Bed temperature mode; skin temperature mode | |
Bed temperature control range | 25.0~37.0℃; 37.1~39.0℃(Span mode) | |
Skin temperature control range | 34.0~37.0℃;37.1~38.0℃(Span mode) | |
Skin temperature sensor display range | 5.0~65.0℃ | |
Heating time | ≤ 50min | |
Temperature variability | ≤ 0.5℃ | |
Temperature uniformity (mattress in horizontal position) | ≤ 0.8℃ | |
Temperature uniformity (mattress in tilted position) | ≤1.0℃ | |
Difference between average incubator temperature and control temperature | ≤1.5℃ | |
Skin temperature sensor accuracy | ±0.3℃ | |
Humidity control | The running time of the tank after it is filled with distilled water | Humidity below 70%RH, at least 24h |
Water tank capacity | 1500ml | |
Humidity display range | 0%RH~99%RH | |
Humidity control range | CAH%RH~90%RH(1% per adjustment) | |
Humidity control accuracy | ±10% | |
Oxygen concentration control | Oxygen concentration display range | 0%~99% |
Oxygen concentration display resolution | 1% | |
Oxygen concentration control accuracy | ±5% oxygen volume concentration | |
Oxygen concentration setting range | 21% ~ 60% (1% per adjustment) | |
Oxygen sensor service life | The maximum use time is 10000h at 100% oxygen concentration | |
Transport storage | Temperature | -20℃~+55℃ |
Atmospheric pressure range | 500hPa~1060hPa | |
Relative humidity | ≤93%RH | |
Packing size/ Gross Weight | Base packing size: 1200*800*870mm 50KgBody packing size: 1100*710*855mm 60Kg | |
The work environment | Relative humidity | 30%RH~75%RH |
Environment temperature | +20℃~+30℃ | |
Pressure range | 700hPa~1060hPa | |
Service altitude | ≤2000m | |
Overvoltage category | Ⅱ | |
Pollution level | 2 | |
Ambient air velocity | ≤ 0.3m/s | |
Other indicators | Ambient noise in the infant compartment of the incubator | No more than 55dB(A) at stable temperature |
Carbon dioxide concentration in the infant compartment | A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL /min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0 5% after stabilization | |
The velocity of air flow over the baby mattress | ≤0.35m/s | |
Generalalarm | Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm | |
System alarm | Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure |
Configuration
Model | BK-3201(I) | BK-3201(II) |
Temp. Control | Bed/Skin temperature | Bed/Skin temperature |
Display | LCD | LCD |
Bed Temp. Control Range | 25℃-39℃ | 25℃-39℃ |
Skin Temp. Control Range | 34℃-38℃ | / |
Humidity Control Range | CAH%~99%RH | CAH%~99%RH |
Oxygen Control Range | 21%-99% | / |
Cabinet | Yes | Yes |
Features
LCD display
Double control modes of bed temperature and skin temperature
Double-layer thermostatic cover, automatic air curtain device
Humidity control function
Air & Oxygen blender
Oxygen supply system
Baby cot is infinitely adjustable
24 kinds of sound and light alarm, comprehensive protection of baby safetyBeing supported by an advanced and specialist IT team, we could give technical support on pre-sales & after-sales services for Top Quality China Hospital Movable Types Baby Medical Phototherapy Unit Neonatal Infant Radiant Warmer Price Infant Incubator CE Approved, For anyone who is fascinated in any items, be sure to truly feel totally free to speak to us for further more details or be sure to deliver us email immediately, we will reply you in 24 hrs as well as the most effective quotation will probably be provided.
Top Quality China Infant Incubator, Baby Incubator, Now, with the development of internet, and the trend of internationalization, we have decided to extend business to overseas market. With the propose of bringing more profits to oversea customers by providing directly abroad. So we have changed our mind, from home to abroad, hope to give our customers more profit, and looking forward to more chance to make business.