-
New Arrival China Automated Nucleic Acid Extractor - OLABO Nucleic Acid Extraction System/DNA RNA BK-HS32 – OLABO
Parameter Model BK-HS32 Multi-mode Operation List mode, shortcut, view mode Processing Volume 20µL-1000µL Sample Throughput 1-32 Magnetic Bead Recovery >98% Extracting the Difference Between Holes CV≤3% Heating Temperature 8 independent heating modules, customize lysis and elution temperature (temperature range) according to your needs Oscillating Mixing Low,medium and high third gears are adjustable, and the fluctuation range can be adjusted with the reagent volume Re... -
Factory wholesale Microwell Plate Reader - Bk-200mini(NEW BK-200) Auto Chemistry Analyzer – OLABO
Parameter Model BK-200 Overall Performance Throughput 200 Tests/hour Analysis Method End-point, Fixed-time, Rate(Kinetic) Certification CE, ISO9001, ISO14001, ISO13485 Sample & Reagent System Sample Positions 37 sample positions Reagent Positions 28 reagent positions Sample Volume 2~70μl Reagent Volume 20~350μl Probe Teflon coating ,with anti-collision function, liquid leveldetection function Probe Washing Automatic washing interior and exterior Reagent Cooling R... -
Factory Price For Horizontal And Vertical Autoclave - OLABO Manufacturer Vertical Autoclave For Lab – OLABO
Parameter Model BKQ-B50II BKQ-B75II BKQ-B100II BKQ-B120II Capacity 50L 75L 100L 120L Chamber Size(mm) φ386*514 φ386*694 φ386*874 φ386*1054 Chamber Material SUS304 Designed Pressure 0.28Mpa Designed Temp 150℃ Working Pressure 0.22MPa Working temp. 105~136℃ Temp. Displayaccuracy ±0.1℃ Timing range 0~999min Dynamic Pulse Exhaust Times 0~9 times Dynamic Pulse Exhaust Temp. 105~134℃ Dissolution Temp. Range 60~100℃ (programmable) Temp. Holding Rang... -
-
Wholesale Price China Microplate Washer Price - Medical Equipment Portable Elisa Microplate Reader – OLABO
Parameter Measurement channel Vertical 8-channel optical path Wavelength Range 400~800 nm Filter Standard 405, 450, 492, 630nm standard filters, other wavelengths are optional. The filter disc supports the loading of 10 filters. Reading range 0.000~4.000 Abs Linear range 0.000~3.000 Abs Repeatability of absorbency CV≤1.0% Stability ≤±0.003Abs Accuracy of absorbency When the absorbance value is [0.0 ~ 1.0], the error is ≤ ±0.02Abs When the absorbance value is [1.0 ~ 2.0], ... -
PriceList for Dna Rna Extraction Machine - BNP Series Nucleic Acid Extractor – OLABO
Parameter Model BNP32 BNP48 Sample Quantity 32 48 Processing Volume 20μL-1000μL Sample Volume 20-500μL Sample Throughput 1-32 Magnetic Bead Recovery >98% Extracting the Difference Between Holes CV≤3% Heating Temperature 8 independent heating modules, customize lysis and elution temperature (temperature range) according to your needs Oscillating Mixing Low,medium and high third gears are adjustable, and the fluctuation range can be adjusted with the reagent volume... -
-
-
2021 Good Quality Semi Auto Chemistry Analyzer Price - OLABO Laboratory Horizontal/Vertical Electrophoresis Power Supply – OLABO
Parameter Output specifications:voltage:5-300 V;current:1-500 mA;power:1-150 W Output Resolution:voltage 1 V、current 1 mA、power 1 W LCD screen displays Timer:1~999 min Dimensions (L*W*H):308*242*100mm Advantage *Automatic match function: Once set the constant value of any one of the voltage, current or power the other two are automatically matched. You needn’t set up all three parameters each time and won’t worry about miss set for the other two once set one constant; *Micro-... -
PriceList for Dna Rna Extraction Machine - OLABO Automatic Nucleic Acid Extraction System BK-HS96 – OLABO
Parameter Model BK-HS96 Nucleic Acid Extraction Method Paramagnetic particle method Sample Capacity 96-well Sample Volume 20-1000ul Extraction Time 15min-60min Magnetic Bead Recovery ≥98% Magnetic Flux of Bar 3000-6000Gs,can change others Operating Temperature RT-105℃ Shock Function Yes Temperature Accuracy 0.1℃ Sample Protection Function Power on self-check, power off protection, high-temperature alarm, over-temperature protection Disinfection Method UV Light S... -
High definition Automated Rna Extraction System - BNP Series Nucleic Acid Extractor – OLABO
Parameter Model BNP32 BNP48 Sample Quantity 32 48 Processing Volume 20μL-1000μL Sample Volume 20-500μL Sample Throughput 1-32 Magnetic Bead Recovery >98% Extracting the Difference Between Holes CV≤3% Heating Temperature 8 independent heating modules, customize lysis and elution temperature (temperature range) according to your needs Oscillating Mixing Low,medium and high third gears are adjustable, and the fluctuation range can be adjusted with the reagent volume... -
Best Price for Shaker Incubator For Cell Culture - OLABO Blast Drying Oven – OLABO
Parameter Model DHG-9050A DHG-9070A DHG-9140A DHG-9250A DHG-9640A DHG-9960A Temp. Range(℃) RT+10-300 RT+10-300 RT+10-300 RT+10-300 RT+10-300 RT+10-300 Capacity(L) 43 71 136 225 640 960 InternalSize(W*D*H)mm 350*350*350 450*350*450 550*450*550 600*500*750 800*800*1000 1000*800*1200 External Size(W*D*H)mm 630*590*530 730*600*630 830*710*740 880*760*950 1130*970*1320 1350*1000*1520 Shelves No. 2 2 2 3 3 3 Power Consumption(W) 1600 2500 3000 4000 6000 7500 Net/Gross Weig... -
Factory source Laminar Flow Hood Cell Culture - OLABO Manufacturer Ducted Fume-Hood (A) For Laboratory – OLABO
Parameter Model FH1000(A) FH1200(A) FH1500(A) FH1800(A) External Size (W*D*H) 1040*800*2200mm 1240*800*2200mm 1540*800*2200mm 1840*800*2200mm Internal Size (W*D*H) 820*670*730mm 1020*670*730mm 1320*670*730mm 1620*670*730mm Work Surface Height 850mm Max Opening 520mm Air Velocity 0.3~0.8m/s Noise ≤68dB Exhaust Duct PVC, Standard length: 4 meters. Φ300mm LED Lamp 8W*1 12W*1 16W*1 16W*1 UV Lamp Emission of 253.7 nanometers for most efficient decontamination Bl... -
China wholesale Medical Sterilizer Machine - OLABO Manufacturer Lab Vertical Autoclave For PCR Lab – OLABO
Parameter Model BKQ-B50L BKQ-B75L Capacity 50L 75L Chamber Size(mm) φ386*490 φ386*670 Chamber Material SUS304 Max Designed Pressure 0.28MPa Max Designed Temp 150℃ Working Pressure 0.22MPa Working temp. 80℃-136℃ Temp. Accuracy 0.1℃ Noise ≤65dB Power consumption 5.5KW Power Supply AC110/220V±10%,50/60Hz External Size(W*D*H)mm 700*610*1100 Packing size(W*D*H)mm 800*715*1270 Net Weight(kg) 140 147 Features ● Standard built-in printer. ● Deionized water interf... -
Low MOQ for Incubator In The Laboratory - OLABO ATP Rapid Fluorescence Detector – OLABO
Parameter Examination range 0 to 9999 RLU Sensitivity of detection 4X10-18 mol ATP Detecting interference ±5﹪or ±5 RLUs The number of result limits that can be set 100 Storage size More than 2000 test results Testing time Adjustable from 1 to 15 seconds Data interface USB interface, EIA—232 compatible Lower limit of detection 1.4CFU Rated voltage Rated voltage 3.3V Power supply 2 AA dry batteries Continuous readings At least 2000 test results Instrument size 192mm×... -
Trending Products Incubator For Bacterial Culture - PCR Laboratory Metal Dry Bath Incubator for Lab – OLABO
Parameter Model OLB-DH300 Temp setting range 0℃~100℃ Temp range RT+5℃~100℃ Time range 1min ~ 99h59min/∞ Temp accuracy ≤±0.3℃ Display accuracy 0.1℃ Temp uniformity ≤±0.3℃ Heating time ≤12min(from 25℃ to 100℃) Multi points running Yes(Max 5points) Multi points running circularly Yes(Max 99times) Auto heating Yes Auto running Yes Auto resume to run Yes Power 150W Voltage AC220V or AC110V / 50-60HZ Fuse 250V 3A Ф5*20 Dimension(mm) 260*195*150 Weight 2... -
OEM/ODM Supplier Bacteriological Incubator Price - China Manufacturer Laboratory Mini Vortex Portable Mixer – OLABO
Parameter Model VORTEX-1 VORTEX-2 VORTEX-3 VORTEX-4 Oscillation mode circumference circumference circumference circumference Turnover diameter 4mm 4.5mm 4 mm 4.8mm Range of rotation 0~2500rpm Single-hole plate: 0~1500rpm Double orifice plate: 0~1000rpm 0~2500rpm 0~3000rpm Speed display Scale Scale Scale Scale Enclosure rating IP21 IP21 IP21 IP21 Motor type Shaded pole motor Brushless DC motor Shaded pole motor Brushless DC motor Voltage 100~120V/200~240V 50/60Hz 100~240V... -
Special Price for Incubator Temperature In Microbiology - OLABO Circulating Water Vacuum Pump For Lab – OLABO
Parameter Model SHZ-DⅢ Double gauge double pumping SHZ-DⅢ Four gauge four pumping Consumption 180W 370W Power Supply 220V 220V Circulating Pump Flow 20L/MIN 40L/MIN PumpLift 8M 12M Material Anti-corrosion Anti-corrosion Pump Head 2 4 Speed of Evacuation 10L/MIN 10L/MIN Vacuum 0.098MPA 0.098MPA Capacity 15L 15L Size 400*280*420 400*280*420 Weight 15KG 17KG -
China Manufacturer for Incubator Shaker Manufacturers - OLABO Laboratory Heating Metal Dry Bath Incubator – OLABO
Parameter Model BJPX-DB2 BJPX-DB4 Heating block capacity 2 modules 4 modules Temperature control PID digital temperature control Temperature control ra RT+5°C -160°C Temperature control ac ±0.5℃(40℃) Temperature uniformity ±1.0℃(40℃) Display accuracy 0.1℃ Timing range 1~9999 minutes (hours) or continuous operation Heating time ≤20 minutes(30℃ to 130℃) ≤30 minutes(30℃ to 160℃) Voltage 220VAC±10% or 110VAC±10% 50/60Hz Size 280*260*120 mm 502*260*120 mm ... -
China Factory for Co2 Incubator Use - OLABO Filling Peristaltic Pump Liquid Dispensing Peristaltic Pump – OLABO
Parameter Drive model BG600-S Speed range 0.1~600rpm(reversible) speed resolution 0.1rpm Flow range 1.3-12000ml/min Filling Accuracy <±0.5% Flow calibration Yes Control Method Rotary encoded knob Display Mode 4-LED display Suckback speed 10~300rpm Power supply AC220V±10%(standard) or AC110V±10%(optional) Power consumption <500W Environment Temperature 0~40℃ Relatively Humidity <80%, No condensation Drive size 345*232*226mm Drive weight 17.5kg Motor typ...