-
100% Original Chemical Analyser - Medical Equipment Portable Elisa Microplate Reader – OLABO
Parameter Measurement channel Vertical 8-channel optical path Wavelength Range 400~800 nm Filter Standard 405, 450, 492, 630nm standard filters, other wavelengths are optional. The filter disc supports the loading of 10 filters. Reading range 0.000~4.000 Abs Linear range 0.000~3.000 Abs Repeatability of absorbency CV≤1.0% Stability ≤±0.003Abs Accuracy of absorbency When the absorbance value is [0.0 ~ 1.0], the error is ≤ ±0.02Abs When the absorbance value is [1.0 ~ 2.0], ... -
Factory Free sample Refrigerator For Medical Store - OLABO Vaccine and Blood Biosafety Transport Box for Hospital – OLABO
Parameter Model OLB-L6 OLB-L12 External Size(W*D*H) 330*235*275mm 400*250*300mm Internal Size(W*D*H) 240*145*180mm 330*170*230mm Capacity 6L 12L Internal and external materials PP Insulation material PU polyurethane integral foaming Temperature type Cold storage:2-8℃ Freezing:-12~-22℃ Number of specimens 19 samples at one time 38 samples at one time Freezing characteristics When frozen into solid, the maximum thickness of the cold source is not more than 15% of the unf... -
Hot sale Elisa Reader And Washer Uses - 400T / H Auto Chemistry Analyzer BK-400 – OLABO
Parameter Model BK-400 Overall Throughput 400 Test/hour Performance Analysis Method End-point, Fixed-time, Rate(Kinetic), Turbidimetry Certification CE, ISO9001, ISO14001, ISO13485 Sample Positions 60 or 90 sample positions, built-in barcode system available Sample & Reagent System Reagent Positions 45 refrigerated reagent positions Sample Volume 2~70μl Reagent Volume 20~350μl Probe Teflon coating, with anti-collision function, liquid leveldetection function ... -
Low price for Autoclave For Dental Clinic - OLABO Manufacturer Vertical Autoclave For Lab – OLABO
Parameter Model BKQ-B50II BKQ-B75II BKQ-B100II BKQ-B120II Capacity 50L 75L 100L 120L Chamber Size(mm) φ386*514 φ386*694 φ386*874 φ386*1054 Chamber Material SUS304 Designed Pressure 0.28Mpa Designed Temp 150℃ Working Pressure 0.22MPa Working temp. 105~136℃ Temp. Displayaccuracy ±0.1℃ Timing range 0~999min Dynamic Pulse Exhaust Times 0~9 times Dynamic Pulse Exhaust Temp. 105~134℃ Dissolution Temp. Range 60~100℃ (programmable) Temp. Holding Rang... -
PriceList for Scientific Incubator - OLABO Medical Dental Plastic Sealing Machine for Hospital – OLABO
Parameter Model MY100-A Sealing Speed 10m/min Power Supply 220V/50Hz Sealing Width 12mm Power Supply 500W Dimension 490*240*140mm Seal Margin 0~35mm(Adjustable) Operating temperature 60~220℃ Weight 12KG Advantage *Automatic control, continuous sealing, temperature control accuracy ±1% *High-speed heating design, room temperature ~180℃ heating up less than 40s *Plate heating element, can be dry burning, high temperature resistance, long life, high thermal effi... -
Factory Supply Incubator Oven - China Manufacturer Laboratory Mini Vortex Portable Mixer – OLABO
Parameter Model VORTEX-1 VORTEX-2 VORTEX-3 VORTEX-4 Oscillation mode circumference circumference circumference circumference Turnover diameter 4mm 4.5mm 4 mm 4.8mm Range of rotation 0~2500rpm Single-hole plate: 0~1500rpm Double orifice plate: 0~1000rpm 0~2500rpm 0~3000rpm Speed display Scale Scale Scale Scale Enclosure rating IP21 IP21 IP21 IP21 Motor type Shaded pole motor Brushless DC motor Shaded pole motor Brushless DC motor Voltage 100~120V/200~240V 50/60Hz 100... -
Factory Cheap Hot Automated Nucleic Acid Extraction System - BNP Series Nucleic Acid Extractor – OLABO
Parameter Model BNP32 BNP48 Sample Quantity 32 48 Processing Volume 20μL-1000μL Sample Volume 20-500μL Sample Throughput 1-32 Magnetic Bead Recovery >98% Extracting the Difference Between Holes CV≤3% Heating Temperature 8 independent heating modules, customize lysis and elution temperature (temperature range) according to your needs Oscillating Mixing Low,medium and high third gears are adjustable, and the fluctuation range can be adjusted with the reagent volume... -
High Performance Incubator Temperature Range In Microbiology - PCR Laboratory Metal Dry Bath Incubator for Lab – OLABO
Parameter Model OLB-DH300 Temp setting range 0℃~100℃ Temp range RT+5℃~100℃ Time range 1min ~ 99h59min/∞ Temp accuracy ≤±0.3℃ Display accuracy 0.1℃ Temp uniformity ≤±0.3℃ Heating time ≤12min(from 25℃ to 100℃) Multi points running Yes(Max 5points) Multi points running circularly Yes(Max 99times) Auto heating Yes Auto running Yes Auto resume to run Yes Power 150W Voltage AC220V or AC110V / 50-60HZ Fuse 250V 3A Ф5*20 Dimension(mm) 260*195*150 Weight 2... -
Lowest Price for Lab Line Dry Bath Incubator - OLABO Portable Digital UV-VIS Spectrophotometer 752N – OLABO
Parameter Model 752N Display LCD screen Metering method Single beam Monochromator Self-collimation Focal length 160mm Grating 1200 lines/mm Detector Imported photocell Spectral bandwidth 4nm Wavelength setting Manual Wavelength range 200 ~ 1000nm Wavelength accuracy ±2nm Wavelength repeatability ≤1nm Light source switching wavelength 340nm Stray light ≤0.1% (T) (measured with Nal at 220nm) (measured with NaNO2 at 360nm) Light source Tungsten lamp and deut... -
-
China Supplier Tissue Culture Hood - Class III Biological Safety Cabinet – OLABO
Parameter Model BSC-1100IIIX BSC-1500IIIX External Size(W*D*H) 1540*880*2000 mm 1790*880*2080 mm Internal Size(W*D*H) 910*650*660 mm 1165*650*660 mm Pass Box Size(W*D*H) Internal Size:430*330*355mm External Size:575*425*495mm Gloves One pair of 800mm butyl rubber gloves Front Window 8 mm toughened glass, anti-ultraviolet radiation Display LCD display Pre-filter Polyester fiber, washable Pressure ≥ negative120 Pa ULPA Filter Air supply filter: Efficiency 99.9995%... -
-
High Quality for Cell Culture Laminar Flow Hood - Horizontal Laminar Flow Cabinet – OLABO
Parameter Model BBS-H1300 BBS-H1800 External Size(W*D*H) 1300*820*2040mm 1800*820*2070mm Internal Size(W*D*H) 1200*500*570mm 1700*500*570mm Work Surface Height 750mm Display LCD Display Airflow Velocity Average of 0.3~0.5m/s Material Main Body: Cold-rolled steel with anti-bacteria powder coating Work Table:304 stainless steel Side and Front Window: 5mm toughened glass, anti-UV Pre-filter Polyester fiber, washable HEPA Filter 99.999% efficiency at 0.3um N... -
OEM/ODM Factory Autoclave Machine For Clinic - OLABO Manufacturer UV Air Sterilizer – OLABO
Parameter Model BK-B-600 BK-B-800 BK-B-1000 Circulating Air ≥600m3/h ≥800m3/h ≥1000m3/h Noise ≤55dB O3 Residue ≤0.0074mg/m3 Applicable Room ≤60m3 ≤80m3 ≤100m3 Ultraviolet Leakage ≤5μw/cm2 Working Environment Temp.Range -10℃~40℃ Humidity ≤80% Atmosphere Pressure 60KPa~106KPa Consumption ≤350W ≤400W Power Supply AC110/220V±10%, 50/60Hz External Size(W*D*H)mm 1000*410*195 1000*450*195 Packing Size(W*D*H)mm 1100*520*240 1150*560*240 Gross Weight(kg) 27.5 33 ... -
Low price for Fully Auto Biochemistry Analyzer - Nucleic Acid Extraction Kit – OLABO
Parameter Name Specification Note Mark Nucleic Acid Extraction Kit I 50T/Box Manual Nucleic Acid Extraction Kit II 64T/Box Auto for BK-HS32 Nucleic Acid Extraction Kit III 96T/Box Auto For BK-HS96 Nucleic Acid Extraction Kit IV 48/96T/Box Auto for BK-AutoHS96 Nucleic Acid Extraction Kit V 32T/Box Auto for BNP-32&48 Features 1.The magnetic beads and buffer system with unique separation effect can be used to extract high-purity viral DNA/RNA from samples quickly, highly sen... -
Factory best selling Elisa Reader Use - Medical Equipment Portable Elisa Microplate Reader – OLABO
Parameter Measurement channel Vertical 8-channel optical path Wavelength Range 400~800 nm Filter Standard 405, 450, 492, 630nm standard filters, other wavelengths are optional. The filter disc supports the loading of 10 filters. Reading range 0.000~4.000 Abs Linear range 0.000~3.000 Abs Repeatability of absorbency CV≤1.0% Stability ≤±0.003Abs Accuracy of absorbency When the absorbance value is [0.0 ~ 1.0], the error is ≤ ±0.02Abs When the absorbance value is [1.0 ~ 2.0], ... -
Factory wholesale Fully Automated Chemistry Analyzer - BK-200 (NEW BK-280) Auto Chemistry Analyzer – OLABO
Model BK-280 Overall Performance Throughput 200Tests/Hour Analysis Method End-point, Fixed-time, Rate(Kinetic), Turbidimetry Certificates CE, ISO9001, ISO14001, ISO13485 Sample & Reagent Unit Sample Positions 49 sample positions Reagent Positions 56 reagent positions Probewashing Automaticwashing interior and exterior ReagentCooling Refrigerated tray with independent switch Reaction System Temperature Control 37±0.1℃, real-time monitor Cuvettes 120 reusable cuvette... -
New Fashion Design for Orbital Shaker Incubator Price - OLABO TOP sales Manual Rotary Microtome – OLABO
Parameter Model BK-2258 BK-2218 BK-2268 Function Sectioning, trimming, fast forward, fast backward, quick conversion; automatic retraction (Only for BK-2268). Specimen Retraction / / 60μm (on/off) Sectioning Thickness Range 0~60μm 0~60μm 0~60μm 0~2μm increment 0.5μm 0~10μm increment 1μm 0~20μm increment 1μm 2~10μm increment 1μm 10~20μm increment 2μm 20~60μm increment 5μm 10~20μm increment 2μm 20~60μm increment 5μm 20~60μm increment 5μm Trimming Thickness ... -
2021 China New Design Automated Plate Washer - OLABO PCR Thermal Cycler – OLABO
Parameter Model TEC01 Capacity 96 Reaction Volume 10~200ul Tube Type 96×0.2mlPCR plate, 8×0.2ml PCR tube Block Temperature Range 4℃~105℃ Heat Lid Temperature Range 30℃~110℃, When the set temperature is lower than 30°, the Heat Lid will be closed automatically Display Resolution ±0.1℃ Temperature Accuracy ≤0.5℃ Temperature Uniformity ≤1℃ Block Material Aluminum Gradient Range 30~99℃ Temperature Differential Range 1~42℃ Program A single program can be up to 30 ste... -
Special Price for Laminar Flow Cabinet Use - Class III Biological Safety Cabinet – OLABO
Parameter Model BSC-1100IIIX BSC-1500IIIX External Size(W*D*H) 1540*880*2000 mm 1790*880*2080 mm Internal Size(W*D*H) 910*650*660 mm 1165*650*660 mm Pass Box Size(W*D*H) Internal Size:430*330*355mm External Size:575*425*495mm Gloves One pair of 800mm butyl rubber gloves Front Window 8 mm toughened glass, anti-ultraviolet radiation Display LCD display Pre-filter Polyester fiber, washable Pressure ≥ negative120 Pa ULPA Filter Air supply filter: Efficiency 99.9995%...