Factory source Laminar Flow Hood Cell Culture - Mini PCR Work Station – OLABO
Factory source Laminar Flow Hood Cell Culture - Mini PCR Work Station – OLABO Detail:
Advantage
1.The multi-function console is divided into three areas, and the areas do not interfere with each other; at the same time, the three areas are closely designed to reduce the sample transfer time between areas and improve the efficiency of rapid nucleic acid detection.
2.The reagent preparation area is a positive pressure environment, which can protect the reagent preparation from external pollution and protect the reagent.
3.The specimen preparation area is a negative pressure environment, which can not only protect personnel from harmful aerosol infection, but also protect samples from external pollution, and also protect the external environment from pollution.
4.The amplification analysis area is a negative pressure environment, which can not only protect personnel from harmful aerosol infection, but also protect the external environment from pollution
PCR laboratory
1.Clean bench; 2. Medicine refrigerator; 3. UV Disinfection trolley; 4. Low temperature refrigerator; 5. Metal bath; 6. Centrifuge; 7. Water bath; 8. Nucleic extractor; 9. Pipette; 10. biosafety cabinet; 11. PCR machine; 12. autoclave; 13.Vortex mixer
area | product | function | quantity | brand | Model |
Reagent preparation area | Clean bench | Configure reagents | 1 | OLABO | BBS-SDC |
Centrifuge | Centrifuge samples | 1 | OLABO | Mini-12 | |
Vortex mixer | Mix the sample | 1 | OLABO | 88882010 | |
Metal bath | Reagent dissolving and heating | 1 | OLABO | 88870005 | |
Pipette | Pipetting | 4 | OLABO | 0.5-10µl | |
10-100μl | |||||
20-200μl | |||||
100-1000μl | |||||
Pipette holder | Place the pipette | 1 | OLABO | Linear | |
Low temperature refrigerator | Store reagents | 1 | OLABO | BDF-25V270 | |
Medicine refrigerator | Store reagents | 1 | OLABO | BYC-310 | |
UV disinfection Trolley | Space disinfection | 1 | OLABO | MF-Ⅱ-ZW30S19W | |
Biosafety transport box | Sample transportation | 1 | OLABO | QBLL0812 | |
Specimen preparation area | Biological safety cabinet | Sample processing | 1 | OLABO | BSC-1500IIB2-X |
Water bath | Sample inactivation | 1 | OLABO | HH-W600 | |
Vortex mixer | Mix the sample | 1 | OLABO | 88882010 | |
Centrifuge | Sample centrifugation | 1 | OLABO | TG-16W | |
TGL-16M | |||||
OLABO | Mini-12 | ||||
Pipette | Pipetting | 4 | OLABO | 0.5-10µl | |
10-100μl | |||||
20-200μl | |||||
100-1000μl | |||||
Pipette holder | Place the pipette | 1 | OLABO | Linear | |
Nucleic Acid Extractor | Extract nucleic acid | 1 | OLABO | BNP96 | |
Low temperature refrigerator | Sample storage | 1 | OLABO | BDF-86V348 | |
Medicine refrigerator | Reagent storage | 1 | OLABO | BYC-310 | |
UV disinfection Trolley | Space disinfection | 1 | OLABO | MF-Ⅱ-ZW30S19W | |
amplification analysis area | PCR machine | Sample amplification test | 1 | OLABO | MA-6000 |
Low temperature refrigerator | Store samples | 1 | OLABO | BDF-25V270 | |
UV disinfection Trolley | Space sterilization | 1 | OLABO | MF-Ⅱ-ZW30S19W | |
Disinfection area | Autoclave | Disinfection of surgical instruments | 1 | OLABO | BKQ-B75II |
Experimental consumables | Tip | Use with pipette | According to actual needs | OLABO | TF-100-R-S |
TF-1000-R-S | |||||
TF-300-R-S | |||||
TF-200-R-S | |||||
PCR tube | Use with a fluorescent quantitative PCR instrument | According to actual needs | OLABO | PCR-0208-C | |
PCR-2CP-RT-C | |||||
Centrifuge tube | Store reagent samples or use with centrifuge | According to actual needs | OLABO | MCT-150-C | |
Sampling tube | Collect samples | 1 | OLABO | ||
Nucleic Acid Extraction Kit | Use with nucleic acid extractor | According to actual needs | OLABO | ||
Protective consumables | Medical masks | Protective Equipment | According to actual needs | OLABO | |
protective suit | Protective Equipment | According to actual needs | OLABO | ||
Disposable isolation gown | Protective Equipment | According to actual needs | OLABO | ||
Gloves | Protective Equipment | According to actual needs | OLABO | ||
Alcohol | Disinfection supplies | According to actual needs | OLABO | 500ml | |
Hand sanitizer | Disinfection supplies | According to actual needs | OLABO | 500ml |
PCR laboratory
1. P2 sterile room (excluding buffer room) is equipped with a set of clean air-conditioning system.
2. The storage room for one-time change of shoes and rain gear, the secondary dressing room, the washing room and the buffer room are each equipped with a split purification air-conditioning system and exhaust fan.
3. The outdoor fresh air enters the computer room through the primary filter, and then is sent to the high efficiency filter (supply vent) on the top of the clean room through the air conditioner, medium-efficiency filter, and pressurized fan. Each vent is equipped with air volume adjustment. Valve for air volume distribution and pressure difference adjustment.
4. The air outlet at the end of the air exhaust system is 0.3 meters above the ground, and there is an air volume regulating valve for air volume adjustment. The exhaust main pipe must be installed with a non-return room to prevent the exhaust air from flowing backward.
5. The temperature probe is set in the main return air duct.
Product detail pictures:






Related Product Guide:
We believe that prolonged expression partnership is really a result of top of the range, value added support, rich encounter and personal contact for Factory source Laminar Flow Hood Cell Culture - Mini PCR Work Station – OLABO, The product will supply to all over the world, such as: Johor, Kenya, Luxemburg, We are proud to supply our products to every auto fan all around the world with our flexible, fast efficient services and strictest quality control standard which has always approved and praised by customers.

This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
